Domenii de iesire/Ch |
+6V |
+25V |
-25V | ||
| |||||
Tensiune: |
0 pana la +6V |
0 pana la +25V |
0 pana la -25V | ||
Curent: |
0 pana la 5A |
0 pana la 1A |
0 pana la 1A | ||
Protectie supratensiune |
0.1V pana la 6.5V |
0.1V pana la 27V |
-0.1V pana la -27V | ||
Protectie supracurent |
0.1A pana la 5.5A |
0.1A pana la 1.2A |
0.1A pana la 1.2A | ||
Stabilitate la variatia sarcinii ± (% iesire + offset) | |||||
Tensiune: |
< 0.01% + 2mV | ||||
Curent: |
< 0.01% + 250μA | ||||
Stabilitate la variatia alimentarii ±(% iesire + offset) | |||||
Tensiune: |
< 0.01% + 2mV | ||||
Curent: |
< 0.01% + 250μA | ||||
Riplu si zgomot (20Hz pana la 20MHz): | |||||
Mod normal tensiune |
< 350μV rms / 2mVvv | ||||
Mod normal curent |
<2mA rms |
< 500μA rms | |||
Mod comun curent |
< 1.5μA rms | ||||
Exactitate la 12 luni (25°C ± 5°C) ± (% iesire + offset) | |||||
Programare |
Tensiune |
0.1% + 5mV |
0.05% + 20mV | ||
Curent |
0.2% + 10mA |
0.15% + 4mA | |||
Citire |
Tensiune |
0.1% + 5mV |
0.05% + 10mV | ||
Curent |
0.2% + 10mA |
0.15% + 4mA | |||
Rezolutie: | |||||
Programare |
0.5mV / 0.5mA |
1.5mV / 0.1mA | |||
Citire: |
0.5mV / 0.5mA |
1.5mV / 0.1mA | |||
Masurare: |
1mV / 1mA |
10mV / 1mA | |||
Timp de raspuns tranzienti: | |||||
Este nevoie de mai putin de 50μs pentru recuperarea tensiunii in domeniul 15mV in timpul modificarii iesirii de curent de la sarcina maxima pana la jumatate din sarcinsa si invers | |||||
Cadere de tensiune: pana la 1V pe fiecare sonda | |||||
Timp de procesare comanda: | |||||
< 50ms | |||||
Coeficient de temperatura per °C (% iesire + offset) | |||||
Tensiune |
0.01% + 2mV |
0.01% + 3mV | |||
Curent |
0.02% + 3mA |
0.01% + 0.5mA | |||
Stabilitate ±(% iesire + offset) | |||||
Tensiune: |
0.03% + 1mV |
0.02% + 2mV | |||
Curent: |
0.1% + 3mA |
0.05% + 1mA | |||
Viteza de programare a tensiunii | |||||
Crescator |
Sarcina max. |
11ms |
50ms | ||
Fara sarcina |
10ms |
45ms | |||
Descrescator |
Sarcina max. |
13ms |
20ms | ||
Fara sarcina |
200ms |
400ms | |||
OVP / OCP (protectie la supratensiune / protectie la supracurent) | |||||
Exactitate ±(% iesire + offset) |
0.5% + 0.5V / 0.5% + 0.5A | ||||
Timp de activare: |
1.5ms (OVP ≥ 3V); < 10ms (OVP < 3V) < 10ms (OCP) | ||||
Echipament: | |||||
Dimensiuni: |
235mm x 155mm x 384mm | ||||
Greutate: |
8.5kg | ||||
Conditii de mediu: | |||||
Temperatura de operare: |
0°C pana la 40°C | ||||
Metoda de racire: |
Cu ventilator; la temperaturi mari, curentul de iesire este scazut la 50% (la temperatura maxima de 55°C) | ||||
Include la livrare: |
Cablu de alimentare, CD cu manualul de utilizare si ghidul de programare | ||||
Garantie: |
3 ani |
Toate accesoriile au garantie 1 an, inclusiv cele livrate cu instrumentele care au un termen de garantie mai mare.
Pentru modelele la care nu se specifica in mod expres faptul ca includ certificat de etalonare, se poate solicita obtinerea unui certificat, costul depinzand de aparatul etalonat.